MSD Software Manual PRELIMINARY Release Chapter 9 Utility Functions.
9.5 SETUP.
The [SETUP] menu accesses advanced functions in the MSD. This menu will
change according to the hardware.
The setup menu on a MSD600M++ series MSD
9.5.1 External synchronization.
The [SETUP] menu on the MSD600M++ calls a menu from where it is possible
to select external synchronisation.
The MSD family has been designed to run on a fixed internal sample rate at
48kHz. However, in certain situations it is required to synchronise the MSD
against an external source. On the MSD600M++ this source can be an AES
signal connected to the dedicated External Sync Input located on the Utility
Module. All other models supported by this manual it is possible to synchronise
to any of the incoming AES signals. Selecting an external synchronisation
source will force the MSD to follow the sample rate of the sync signal. It is
therefore important to ensure that the external sync sources sample rate does
not exceed 48kHz.
If the MSD is not able to synchronize to the selected signal the warning ‘EXT
SYNC ERROR’ will be shown in the top left corner of the ‘Audio Vector Scope’
window. If the MSD shows this warning the MSD will not function correctly.
External Synchronization on the MSD600M++ is selected from the [SETUP]
menu available from the [UTILITY] menu. On all other models it is selected
from the AES option menu.
PRELIMINARY Release Page 37 of 64.