DK Digital CDB-700 Manual do Utilizador Página 52

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 51
Page 52 of 108
Warnings!
• BL1 is heavy (9.8 kg) To avoid personal injury, DO NOT DROP !
• Do not adjust anything during movement, can cause personal injury !
• LINAK recommend using a safety nut in medical applications !
• A broken chain causes a drop of half the length of actual stroke. Therefore do not overload !
• The BL1 is designed for use in push applications, dynamic “Pull forces can result in damage to the column and cause collapse of the application.
• Do not loosen any screws on the BL1, this can cause collapse of the column !
Technical specification:
Load in push 4 mm spindel : Max. 2000 N See label
Load in push 9 mm spindel : Max. 700 N See label
Load in pull (dynamic): 0N
Load in pull (static) 4 mm spindel: Max. 2000 N
Load in pull (static) 9 mm spindel: Max. 700 N
Bending moment (static) : Max. 500 Nm
Bending moment (dynamic) : Max. 250 Nm
Duty Cycle: 10% Max. 2 min./18 min. See label
Protection class: IPX6
Usage temperature: +5°C to +40°C
Storage temperature: Max. 50°C
...to be continued
BL1 Mounting guidelines:
• BL1 is for use in push applications, and can be mounted in both directions (smallest profile down, or up).
Note: The cable outlet can only be positioned at the end of the small profile.
• It is very simple to mount the BL1 in the application using the 4 mounting holes in both endplates.
• Use 4 self-tapping screws, in each end, for mounting to the application. Use EJOT PT type DG Ø8, screw depth must be min. 30 mm in
aluminium profile. Screw torque: 15 - 17 Nm.
• If the column has been loosened from the application, it is very important that the self-tapping screws are mounted in the same thread,
to ensure the same strength in the thread. Therefore we recommend that the screws are loosened no more than 1 or 2 times.
0.6
0.8
Mounting holes
Mounting holes
Mounting holes
Drain hole
Mounting holes
Drain hole
Drawing no.: 0807000-1
The BL1 is for use in push applications and can be mounted in both directions (smallest profile down, or up).
Note: The cable outlet can only be positioned at the end of the small profile.
The mounting plate in the application must cover the entire top plate of the BL1 and be strong enough to carry the load.
Remember to secure the cable mounted in the top of the column to the application, so that it cannot be pulled out of the column. We
recommend to use LINAK Cable lock kit 0808040, use only screws included in the kit.
Electro Static Discharges!
If painted top and bottom plates are used, there is no electrical connection through the length of the the BL1 column. Therefore, to avoid
ESD issues, consider external potential alignment between the top and bottom of the bed frame.
Vista de página 51