Page 9 of 108
Warning!
Failure to comply with these instructions may result in accidents involving serious personal injury. It is important for everyone who is to
connect, install, or use the systems to have the necessary information and access to the User Manual on www.linak.com.
• If there is visible damage on the product it must not be installed.
• IIf the control box/TWINDRIVE makes unusual noises or smells, switch off the mains voltage immediately.
• The products must only be used in an environment that corresponds to their IP protection.
• The cleaners and disinfectants must not be highly alkaline or acidic (pH value 6-8).
• Irrespective of the load the duty cycle stated in the data sheets, must NOT be exceeded.
• The DESKLINE
®
systems can only be used in push applications.
• The control box/TWINDRIVE must only be connected to the voltage stated on the label.
• System not specified for pull must only be used in push applications.
• Fastening screws and bolts must be correct tightened.
• Do not open the closing device on the TWINDRIVE during operation.
• Specifications on the label must under no circumstances be exesided.
• NOT TO BE OPENED BY UNAUTORIZED PERSONNEL.
• Do only use the actuator within specified working limits.
• Note that during construction of applications, in which the actuator is to be fitted, there must be no possibility of personal injury, for example the
squeezing or fingers or arms.
• If irregularities are observed, the actuator must be replaced.
• If the actuator is used for pull in an application where personal injury can occur, the following is valid: It is the application manufacturer’s
responsibility to incorporate a suitable safety arrangement, which will prevent personal injury from occurring, if the actuator should fail.
• MEDLINE and CARELINE products are rated to operate at an altitude < 2000 m.
Generel assembly instructions
Please read the following safety information carefully. Ensure that all staff who are to connect, mount, or use the actuator are in possession of the
necessary information and that they have access to this assembly instruction.
Persons who do not have the necessary experience or knowledge of the product/products must not use the product/products. Besides, persons with
reduced physical or mental abilities must not use the product/products, unless they are under surveillance or they have been thoroughly instructed in
the use of the apparatus by a person who is responsible for the safety of these persons. Moreover, children must be under surveillance to ensure that
they do not play with the product.
Failing to follow these instructions can result in the actuator suffering damage or being ruined.
• Before you start mounting/dismounting, ensure that the following points are observed:
- The actuator is not in operation.
- The mains current supply is switched off and the plug has been pulled out.
- The actuator is free from loads that could be released during this work.
• Before you put the actuator into operation, check the following:
- The actuator is correctly mounted as indicated in the relevant user instructions.
- The equipment can be freely moved over the actuator’s whole working area.
- The actuator is connected to a mains electricity supply/transformer with the correct voltage and which is dimensioned and adapted to the
actuator in question.
- Ensure that the voltage applied matches to the voltage specified on the actuator label.
- Ensure that the connection bolts can withstand the wear.
- Ensure that the connection bolts are secured safely.
• During operation
- Listen for unusual sounds and watch out for uneven running. Stop the actuator immediately if anything unusual is observed.
- Do not side load the actuator.
- Use only the actuator within the specified working limits.
- Do not step or kick on the actuator.
• When the equipment is not in use
- Switch off the mains supply or pull out the plug in order to prevent unintentional operation.
- Check regularly the actuator and joints for extraordinary wear.
• Note:
- If the actuator is operated as a hand crank, it must be operated by hand, otherwise there is a risk of overloading the actuator and hereby
damage the actuator.
• Note:
- When changing the cables on a LINAK actuator, it is important that this is done carefully, in order to protect the plugs and pins.
Please be sure that the plug is in the right location and fully pressed in before the cable lid is mounted.